  • Measuring principle: PT 100 resistance thermometer
  • Measuring range: -25 to +100 °C
  • Pressure resistance: 600 bar
  • Overload pressure: 900 bar
  • Mechanical connection: G1/4 A DIN 3852
  • Torque value: 20 Nm
  • Parts in contact with medium Mech. conn.: Stainless steel
  • Seal: FPM

The ETS 4000 is a robust electronic temperature transmitter which is particularly suited to measuring temperature in hydraulic applications in industry. The temperature sensor, based on a PT 100 and corresponding evaluation electronics, is capable of measuring temperatures in the range -25 °C to +100 °C.

The sensor has analogue output signals of 4 to 20 mA und 0 to 10 V available as standard to enable integration into modern controls. The pressure resistance up to 600 bar and excellent EMC characteristics make the ETS 4000 ideal for use in harsh conditions.

Special features:

  • Ideal for industrial applications
  • Robust design
  • Excellent EMC characteristics
  • Good long-term stability
  • Standard protection class IP 65

Electronic Temperature Transmitter (With HSI Sensor Recognition) | ETS 4548-H

  • Measuring principle: Silicon semiconductor device
  • Measuring ranges: -25 to +100 °C
  • Pressure resistance: 600 bar
  • Overload pressure: 1000 bar
  • Mechanical connection: G1/4 A DIN 3852
  • Torque value: 20 Nm
  • Parts in contact with medium Mech. conn.: Stainless steel
  • Seal: FPM

The electronic temperature transmitter ETS 4548-H with HSI sensor recognition has been specially developed for use in conjunction with HYDAC measuring instruments HMG 500, HMG 510, HMG 3000 and CMU 1000. For data transmission, the ETS 4548-H has an HSI interface (HYDAC Sensor Interface). The HIS sensors are automatically recognized via the HSI interface by the abovementioned HYDAC measuring instruments and all the necessary basic settings are taken from each sensor.

Like all temperature transmitters in the ETS 4000 series, the ETS 4548-H features a robust design and excellent EMC characteristics. Based on a silicon semiconductor device and corresponding evaluation electronics, the temperature sensor is designed to measure temperatures in the range -25 to +100 °C.

Special features:

  • Automatic recognition by, and voltage supply from, HYDAC measuring instruments HMG 500, HMG 510, HMG 3000 or CMU 1000
  • Automatic transfer of measuring range, measured value and measurement unit
  • Robust design
  • Pressure resistant to 600 bar
  • Excellent EMC characteristics
  • Standard protection class IP 67

Electronic Temperature Transmitter | ETS 7000

  • Measuring principle: Silicon semiconductor device
  • Measuring range: -25 .. +100 °C
  • Pressure resistance: 600 bar
  • Overload pressure: 900 bar
  • Mechanical connection: G1/4 A DIN 3852
  • Torque value: 20 Nm
  • Parts in contact with medium Mech. conn.: Stainless steel
  • Seal: FPM

The ETS 7000 is an electronic temperature transmitter which, due to its compact design, is particularly suited to measuring temperature in hydraulic applications in the industrial and mobile sectors. Based on a silicon semiconductor device and corresponding evaluation electronics, the temperature sensor is designed to measure temperatures in the range -25 to +100 °C.

The sensor has various analogue output signals as standard, e.g. 4 .to 20 mA or 0 to 10 V to enable integration into modern controls through an M12x1 connector. The pressure resistance up to 600 bar and excellent EMC characteristics make the ETS 7000 ideal for use in harsh conditions.

Special features:

  • Ideal for OEM applications
  • Very compact design
  • Excellent EMC characteristics
  • Long-term stability
  • Standard protection class IP 67

Speak to our filtration technology division about your factory automation requirements.

CONTACT US

Need more info?

Send us your requirements:


I agree to receive Bosch Rexroth Africa training and event information

LATEST NEWS

9 January 2025

2025 Hydraulic & Pneumatic Training Calendar

Advance your career with MerSETA-accredited courses for all skill levels.

Read More >
3 December 2024

Reflecting on the highlights of 2024

2024 highlights and recaps available in our newsletter.

Read More >
27 November 2024

Hytec South Africa donates safe sanitation facilities

We installed dignified sanitary stations for children and staff at a KZN school.

Read More >
19 November 2024

We launched a cutting-edge modular training workstation

Training Department has unveiled a state-of-the-art modular training workstation.

Read More >

Read more of the Group’s latest news here.

We use cookies to improve your experience on our website. By using our site you agree to Cookies Policy